Detection range: 300 to 10000ppmm
The characteristics gas: 1000ppmm, isobutane
Sensitivity: R in air / Rin, typical gas ≥ 5
Sensing Resistance: 1KΩ 50ppm toluene to 20KΩ in.
Response time: ≤ 10s
Recovery time: ≤ 30s
Heat resistance: 31Ω ± 3Ω
Heating current: ≤ 180mA
Heating voltage: 5.0V ± 0.2V
Heating power: ≤ 900mW
Measuring voltage: ≤ 24V
Working conditions of ambient temperature: -20 ℃ ~ +55 ℃
Humidity: ≤ 95% RH
Environmental oxygen content: 21%
Storage conditions Temperature: -20 ° C to +70 ° C
Humidity: ≤ 70% RH